[Nov 05, 2021] 300-615 Exam Dumps - Cisco Practice Test Questions
New Real 300-615 Exam Dumps Questions
The Cisco 300-615 exam is the perfect option for those individuals who want to validate their skills in troubleshooting the data center along with its network, storage, automation, operations, and more. This is one of the concentration tests designed for earning the CCNP Data Center certification, which must be taken after the core exam, known as 350-601 DCCOR. For those students who pass only the 300-615 test, the vendor will grant the Cisco Certified Specialist – Data Center Operations certificate.
NEW QUESTION 20
Refer to the exhibit.
After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?
- A. Reboot the switch
- B. Reboot the guestshell
- C. Resync the database
- D. Recreate the guestshell
Answer: B
NEW QUESTION 21
Refer to the exhibit.
The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?
- A. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- B. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- C. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- D. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
Answer: C
Explanation:
Explanation
Need exact snap shot to confirm the following.
The selection of is due to
* SNMP command has the key word "oid".
* The command "switchto vdc Core" show run in "enable" mode, not "config t" mode.
NEW QUESTION 22
Refer to the exhibit.
A PC belongs to VLAN 68 The user experiences a large amount of packet loss when communicating with hosts that are outside of VLAN 68. Which action resolves the problem?
- A. Configure ip arp synchronization on both switches.
- B. Replace HSRP with GLBP
- C. Enable the peer-gateway feature
- D. Remove the HSRP configuration
Answer: C
Explanation:
I assume that the PC is sending traffic with destination MAC of Nexus physical interfaces. If more snap shots about this question are available, please share.
NEW QUESTION 23
An upgrade of protected RPMs from the Bash shell did not take effect. Which action is required for the changes to take effect?
- A. Restart the Bash shell.
- B. Reload the switch.
- C. Disable and reenable the Bash feature.
- D. Upgrade the RPMs from the Guest shell.
Answer: C
NEW QUESTION 24
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.
Answer:
Explanation:

NEW QUESTION 25
Refer to the exhibit.
The script fails to bring up Ethernet 1/2 when Ethernet 1/1 goes down. Which change enables the script to run as intended?
- A. Set the port VLAN
- B. Include an action to manually shut down Ethernet 1/1
- C. Add an action to configure the terminal
- D. Configure an enable action
Answer: C
NEW QUESTION 26
Refer to the exhibit. An engineer discovered a VFC interface in a down state on a Cisco Nexus Switch. Which action resolves the problem?
- A. Update the CNA firmware and driver versions
- B. Reset the Cisco Nexus port toward the file server
- C. Modify the fip keepalive message time to 30 seconds
- D. Change the cable between the switch and the server
Answer: C
Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/ N5K_Troubleshooting_Guide/n5K_ts_fcoe.html
NEW QUESTION 27
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?
- A. Install Server Firmware, then Install Infrastructure Firmware
- B. Install infrastructure Firmware, then Install Hypervisor Firmware.
- C. Install Hypervisor Firmware, then Install Infrastructure Firmware
- D. Install Infrastructure Firmware, then Install Server Firmware.
Answer: D
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Ma
NEW QUESTION 28
An engineer enables the packet postcards feature on a Cisco Nexus 9000 Series Switch but receives this error message:
"Error: Cannot configure postcard when inband-telemetry is configured." Which action resolves the issue?
- A. Disable the software-telemetry feature.
- B. Disable the telemetry feature.
- C. Disable the inband-telemetry feature.
- D. Disable the hardware-telemetry feature.
Answer: D
Explanation:
Section: Management and Operations
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/92x/programmability/ guide/b-cisco-nexus-9000-series-nx-os-programmability-guide-92x/b-cisco-nexus-9000-series-nx-os- programmability-guide-92x_chapter_0100001.html
NEW QUESTION 29
An engineer is troubleshooting a failed DCBX exchange between a server and a Cisco Nexus switch. Which action allows DCBX to successfully negotiate?
- A. Enable PFC.
- B. Enable LLDP.
- C. Enable ETS
- D. Enable Cisco Discovery Protocol.
Answer: B
Explanation:
Section: Storage Network
NEW QUESTION 30
An engineer attempts to register Cisco UCS Manager to Cisco UCS Central, but the registration fails. The engineer can ping Cisco UCS Central from UCS Manager. Which two actions must the engineer attempt to resolve the problem? (Choose two.)
- A. Synchronize the date and time to NTP for Cisco UCS Central and the Cisco UCS domains.
- B. Allow port 443 between Cisco UCS Manager and Cisco UCS Central.
- C. Apply the UCS Central license to UCS Central.
- D. Place Cisco UCS Manager on the same subnet as Cisco UCS Central.
- E. Allow port 9443 between Cisco UCS Manager and Cisco UCS Central.
Answer: A,B
Explanation:
Section: Compute Platforms
NEW QUESTION 31
Refer to the exhibit.
When an engineer inserts 8-Gb FC SFP port 15 on a Cisco UCS Fabric Interconnect, the port fails. What is a possible cause of the issue?
- A. Port 15 is missing a license.
- B. The polarity of the fiber cable is reversed.
- C. Port 15 is configured as an Ethernet port.
- D. Port 15 is configured for 4-Gb FC.
Answer: D
NEW QUESTION 32
Refer to the exhibit.
An engineer is investigating a role mapping issue on a switch. The users report that they cannot view the IP addresses under the tenant "corp". Which action resolves the issue?
- A. Configure the correct secret password between the APIC and the RADIUS server.
- B. Add the updated avpair to include/corp/admin/
- C. Add the users to the RADIUS server.
- D. Update the UNIX ID.
Answer: A
NEW QUESTION 33
An attempt to use a global vNIC redundancy template pair results in a service profile that fails to apply. Which action resolves the issues?
- A. Assign the secondary template first, and then set the peer name.
- B. Assign both templates simultaneously.
- C. Assign the primary template first, and then set the peer name.
- D. Create the peer names before creating the templates.
Answer: C
Explanation:
Section: Compute Platforms
NEW QUESTION 34
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Answer:
Explanation:

NEW QUESTION 35
An engineer removes a VMM domain from an endpoint group called EPG-1, but the distributed port group fails to be deleted. Which action must be taken to resolve the issue?
- A. Remove the remaining EPGs from the VMM domain.
- B. Migrate all virtual machines in the EPG-1 to different port groups.
- C. Migrate all virtual machines in the EPG-1 to different hypervisors.
- D. Remove the port group manually.
Answer: A
NEW QUESTION 36
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?
- A. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - B. 1- Disconnect the power cord
2- Confirm that all cards are properly seated
3- Connect the power cord - C. 1- Disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - D. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are available
3- Connect the power cord and power on the server
Answer: A
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pd
NEW QUESTION 37
Refer to the exhibit.
The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?
- A. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- B. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- C. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- D. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
Answer: C
Explanation:
Explanation
Need exact snap shot to confirm the following.
The selection of is due to
* SNMP command has the key word "oid".
* The command "switchto vdc Core" show run in "enable" mode, not "config t" mode.
NEW QUESTION 38
Refer to the exhibit.
A PC belongs to VLAN 68 The user experiences a large amount of packet loss when communicating with hosts that are outside of VLAN 68. Which action resolves the problem?
- A. Configure ip arp synchronization on both switches.
- B. Replace HSRP with GLBP
- C. Enable the peer-gateway feature
- D. Remove the HSRP configuration
Answer: C
Explanation:
Explanation
I assume that the PC is sending traffic with destination MAC of Nexus physical interfaces. If more snap shots about this question are available, please share.
NEW QUESTION 39
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.
Answer:
Explanation:

NEW QUESTION 40
Refer to the exhibit.
A network engineer traces the packet flow from the Veth991 of a blade server toward the core switch. The switch reports performance issues What is the role of the interface Eth1/7?
- A. IOM host interface
- B. server interface
- C. fabric interconnect uplink interface
- D. IOM network interface
Answer: C
Explanation:
Explanation
E1/7 is border interface, which is used as uplink. All other veth interfaces are SIF, which stands for Server Interface.
NEW QUESTION 41
Drag and drop the commands from the left onto the correct categories on the right.
Answer:
Explanation:

NEW QUESTION 42
......