2021 Realistic Verified 350-601 exam dumps Q&As - 350-601 Free Update [Q46-Q62]

Share

2021 Realistic Verified 350-601 exam dumps Q&As - 350-601 Free Update 

Use Real 350-601 Dumps - 100% Free 350-601 Exam Dumps


Career Opportunities

Excelling in the Cisco 350-601 exam will help you qualify for different technical roles, and some of them are discussed below:

  • Senior data center engineer

    Senior data center engineers are responsible for installing, testing, and maintaining a wide variety of IT communication infrastructure within data centers. These individuals spearhead engineering tasks, design project documentation, and give valuable technical advice to help manage different issues within data center infrastructures. According to ZipRecruiter, a vast majority of senior data center engineers earn an average of $115k annually.

  • Data center network engineer

    A data center network engineer is a competent IT professional with a crucial role in managing the everyday operations of Network Operations Centers (NOC). These individuals interconnect network-centered and physical devices with the required equipment to successfully erect data center facilities. While their job majorly involves streamlining digital connections within the nodes of data center infrastructure, they still have a crucial role in installing or maintaining applications, network servers, and clients using a unified map. This ensures seamless running and monitoring of several data centers under the same environment. At the moment, most of the data center network engineers are earning a mean annual salary of $94k, as stated on ZipRecruiter.

  • Network operations engineer

    Network operations engineers, on the other hand, are tasked with performing a scheduled review of system firmware, iOS, and application software. These individuals manage networks, servers, and other relevant equipment to streamline business processes. In many organizations, they work closely with other support staff to identify and document measurement requirements, troubleshoot different solutions, and provide administrative support in case of incident management or reporting. A typical network operation engineer in the modern IT industry earns up to $93k in the USA, according to PayScale.


Cisco Certified Specialist-Data Center Core

The Cisco Certified Specialist-Data Center Core is a mere recognition for completing the Cisco 350-601 exam. This is an option that the vendor introduced together with the new exam curriculum to ensure candidates are rewarded for their accomplishments. In a nutshell, every professional-level exam will now earn you a certification and a specialist title to complement your skills.


Introduction to Cisco 350-601: Implementing and Operating Cisco Data Center Core Technologies Exam

This 350-601 exam test helps you prepare for the Cisco CCNP Data Center and CCIE Data Center certifications for advanced-level data center roles. In this course, you will master the skills and technologies you need to implement data center compute, LAN, and SAN infrastructure. You will also learn the essentials of automation and security in data centers. You will gain hands-on experience deploying, securing, operating, and maintaining Cisco data center infrastructure including Cisco MDS Switches and Cisco Nexus Switches; Cisco Unified Computing System (Cisco UCS) B-Series Blade Servers, and Cisco UCS C-Series Rack Servers.

 

NEW QUESTION 46
Refer to the exhibit.

Which backup operation type does not include the Preserve Identities feature?

  • A. logical configuration
  • B. system configuration
  • C. full state
  • D. all configuration

Answer: C

 

NEW QUESTION 47
Port security is statically configured on a Cisco Nexus 7700 Series switch and F3 line card. The switch is configured with an Advanced Services license. Which two actions delete secured MAC addresses from the interface? (Choose Two)

  • A. The address must reach the age limit that is configured for the interface.
  • B. The device must be restarted manually.
  • C. Shutdown and then no shutdown must be run on the interface.
  • D. The address must be removed from the configuration.
  • E. The interface must be converted to a routed port.

Answer: D,E

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/6_x/nx-os/security/configuration/guide/b_Cisco_N

 

NEW QUESTION 48
A network engineer must determine the cooling requirements for a Cisco UCS C-Series Rack Server. The server with PCIe cards is configured with a fan configuration policy. Which configuration should be used for the fan policy of the server?

  • A. Option D
  • B. Option B
  • C. Option A
  • D. Option C

Answer: C

 

NEW QUESTION 49
An engineer enters these commands while in EEM on a Cisco Nexus 9000 Series Switch event manager applet Backup-config event timer watchdog time 1800 name timer event cli match "copy running-config startup-config" What is the result of applying this configuration?

  • A. It executes the copy running-config startup-coring command.
  • B. It generates an error because no action is mentioned.
  • C. It blocks the copy running-config startup-config command.
  • D. It saves the running configuration every 1800 seconds.

Answer: B

Explanation:
Section: Automation

 

NEW QUESTION 50
Refer to the exhibit.

Which statement about the default gateway configuration of the vPC is true?

  • A. N7K-2 acts as the default gateway for all traffic.
  • B. Either switch can act as the active default gateway.
  • C. N7K-1 acts as the default gateway for all traffic.
  • D. N7K-2 forwards traffic that is destined for the default gateway by using the peer link.

Answer: B

 

NEW QUESTION 51
Which product includes prebuilt templates that are available to be used to customize fabric deployments?

  • A. Cisco ACI
  • B. Cisco Data Center Network Manager
  • C. Cisco Tetration
  • D. Cisco UCS Manager

Answer: B

Explanation:
Section: Storage Network

 

NEW QUESTION 52
Refer to the exhibit.

What is a characteristic of the UUID in the service profile presented.

  • A. based on the hardware
  • B. unique system generated
  • C. vendor assigned
  • D. allocated from a UUID pool

Answer: C

 

NEW QUESTION 53
An engineer is asked to manage a large-scale data center and collect information from multiple Cisco NX-OS devices using Cisco NX-OS Data Management Engine model. Which technology should be used to accomplish this goal?

  • A. JSON-RPC
  • B. NX Yang
  • C. NX-API REST
  • D. NETCONF

Answer: C

 

NEW QUESTION 54
Refer to the exhibit.

What is the result of implementing this configuration?

  • A. The Fibre Channel interface is configuration for source distribution.
  • B. The Fibre Channel interface is configured for SPAN.
  • C. The Fibre Channel interface is configured for FSPF.
  • D. The Fibre Channel interface is configured for synchronization distribution.

Answer: B

 

NEW QUESTION 55
A DNS server with IP address 192.168.1.1 is deployed in a data center A network engineer must configure a Cisco UCS Fabric Interconnect to use this DNS. Which configuration should be applied?

  • A. Option D
  • B. Option B
  • C. Option A
  • D. Option C

Answer: A

 

NEW QUESTION 56
An engineer deploys a custom guest shell rootfs onto multiple switches. Drag and drop the steps from the left into the correct order on the right.

Answer:

Explanation:

Explanation

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/progammability/guide/b-cisco-nex

 

NEW QUESTION 57
Which two firmware packages are included in the Cisco UCS C-Series Rack-Mount UCS-Managed Server Software bundle? (Choose two.)

  • A. PSU
  • B. BIOS
  • C. CIMC
  • D. third-party
  • E. system

Answer: B,C

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Firmware-Mgmt/

 

NEW QUESTION 58
Due to a major version change, an engineer must perform a software upgrade on a Cisco Nexus Series switch.
Which two technologies can be implemented to reduce disruptions to the network during the upgrade?
(Choose two.)

  • A. vPC
  • B. PAgP
  • C. VDC
  • D. MLAG
  • E. HSRP

Answer: A,D

 

NEW QUESTION 59
Host 1 is in VLAN 100 located is DataCenter 1 and Host2 is in VLAN200 located in DataCenter2. Which OTV VLAN mapping configuration allows Layer 2 connectivity between these two hosts?

  • A. Option D
  • B. Option A
  • C. Option C
  • D. Option B

Answer: D

 

NEW QUESTION 60
Refer to the exhibit.

What is the reason the system-fm-vrrp checkpoint was created?

  • A. The VRRP-enable feature has been disabled.
  • B. The VRRP process crashed and the checkpoint was automatically created.
  • C. The network administrator manually created it.
  • D. The VRRP service restarted and the checkpoint was automatically created.

Answer: A

 

NEW QUESTION 61
An engineer must configure Cisco IMC server management NIC for autonegotiation. Which setting should be selected?

  • A. shared LOM
  • B. shared LOM EXT
  • C. Cisco card
  • D. dedicated

Answer: D

 

NEW QUESTION 62
......

Pass 350-601 exam Updated 139 Questions: https://www.actual4dumps.com/350-601-study-material.html

350-601 Exam Dumps, Test Engine Practice Test Questions: https://drive.google.com/open?id=1j7QJ-THDGN-vrJ1Gvx_EwQVVO4Y79qcA